Models Available:
OEC 9800 |
OEC 9600 |
OEC 9400 |
OEC 9000 |
OEC 8800
OEC 9800
The OEC 9800 led the way for mobile
fluoroscopy applications and innovative X-ray
imaging technology. It was built on the
leadership and experience that comes from having
thousands of systems installed world-wide.
-
Dual 16" Square, Flicker Free 1k X 1k High
Resolution Monitors
-
Tri-Mode 9”/6”/4.5” Image Intensifier
-
Rotating Anode X-ray Tube (0.3mm & 0.6mm)
Focal Spots
-
15
kW, 60 Hz High Frequency Generator
-
20
mA Fluoro Boost
-
High Resolution 1k x 1k CCD Camera
-
1k
x 1k x 16 bit Image Processing
-
63
or 400 Image Storage
-
PreView On-Screen Collimator displays allow
easy collimator positioning without X-ray
exposure
-
MANRS (real-time Motion Artifact and Noise
Reduction System)
-
Digital Zoom Mode. Normal and digital zoom
modes provide 2 or 4 times the image size.
-
Automatic Digital Brightness and Contrast
Controls
-
Last Image Hold (LIH)
-
Output to Floppy Disk
-
Thermal Printer (Optional)
-
DICOM (Optional)
-
Multiple specialty packages available; GSP,
ESP, Vascular, and Neuro Vascular
MMI provides C-Arm repair services for the OEC
9800 throughout Florida
OEC 9600
The OEC 9600 C-Arm is a multi-application
system that provides solutions to the demanding
needs of orthopedic surgery, general surgery,
trauma work and pain management.
-
Dual 16” Square High Resolution Flicker Free
Monitors
-
Tri-Mode 9”/6”/4.5” Image Intensifier
-
Rotating Anode X-ray Tube (0.3mm & 0.6mm)
Focal Spots
-
4.0 kW High Frequency Generator
-
12
mA Fluoro Boost
-
High Resolution CCD Camera
-
10
bit Digital Image Processing
-
200 Image Storage
-
Collimator with dual opposing shutters
-
MARS-Motion Artifact Reduction System
-
Frame Averaging
-
Last Image Hold (LIH)
-
Output to Floppy Disk
-
Thermal Printer
-
Multiple specialty packages available; SP,
GSP, ESP, Vascular and Neuro Vascular
MMI provides C-Arm repair services for the OEC
9600 throughout Florida
OEC 9400
The OEC 9400 C-Arm is a multi-application
system that provides solutions to the demanding
needs of orthopedic surgery, general surgery,
trauma work, and pain management.
-
Dual 17" High Resolution Monitors
-
Tri-Mode 9"/6"/4.5" Image Intensifier
-
Rotating Anode X-ray Tube
-
7.5 KW Full-Wave, 2.5 kHz High Frequency
Generator
-
20
mA Fluoro Boost
-
Vidicon Camera
-
60
Image Storage
-
MARS-Motion Artifact Reduction System
-
Frame Averaging
-
Last Image Hold (LIH)
-
ESP-Expanded Surgical Package
-
Vascular Module can be added
-
Thermal Printer or Matrix Camera
Vascular Module contains all of the above,
plus:
-
4
FPS (frame per second) Cine
-
DSA (Digital Subtraction Angiography)
-
Roadmapping
MMI provides C-Arm repair services for the OEC
9400 throughout Florida
OEC 9000
The OEC 9000 C-Arm comes equipped with the
Expanded Surgical Package which is a
multi-application system that provides solutions
to the demanding needs of orthopedic surgery,
general surgery, trauma work, and pain
management.
-
Dual 15" Hi Resolution Monitors
-
9"/6" Image Intensifier
-
Rotating Anode X-Ray Tube
-
7.5 KW Full-Wave, 2.5 kHz High Frequency
Generator
-
20
mA Fluoro Boost
-
Vidicon Camera
-
60
Image Storage
-
MARS-Motion Artifact Reduction System
-
Frame Averaging
-
Last Image Hold (LIH)
-
ESP-Expanded Surgical Package
-
Angio Plus Module can be added
-
Thermal Printer or Matrix Camera
Angio Plus Module contains all of the above,
plus:
-
DSA (Digital Subtraction Angiography)
-
Roadmapping
MMI provides C-Arm repair
services for the OEC 9000 throughout Florida
OEC 8800
The OEC 8800 C-Arm is a multi-application
system.
-
Dual 16" Square, Flicker Free 1k X 1k High
Resolution Monitors
-
Tri-Mode 9"/6"/4.5" Image Intensifier
-
Stationary Anode X-ray Tube (0.5mm & 1.5mm)
Focal Spots
-
2.2 kW, 20 kHz High Frequency Generator
-
Snapshot up to 10 mA
-
High Resolution 1k x 1k CCD Camera
-
1k
x 1k x 16 bit Image Processing
-
63
or 200 Image Storage
-
PreView On-Screen Collimator displays allow
easy collimator positioning without X-ray
exposure
-
MANRS (real-time Motion Artifact and Noise
Reduction System)
-
Automatic Digital Brightness and Contrast
Controls
-
Last Image Hold (LIH)
-
Output to Floppy Disk
-
Thermal Printer (Optional)
-
DICOM (Optional)
-
Multiple specialty packages available; GSP,
ESP and Vascular
MMI
provides C-Arm repair services for the OEC 8800